277 Volt Systems

This page is intended for general informational use only and should not be used as a substitute for consulting a licensed electrician. While the information is believed to be current and accurate we are not experts and accept no liability for its use.

An Overview of 277 Volt Electrical Systems

Industrial and commercial power is delivered in 120/208-Volt and 277/480-Volt systems. Heating and ventilation systems are run at 480 volts while industrial scale lighting runs at 277 Volts. A 277/480-Volt system powers the industrial and commercial equipment at 480 volts while the 277 volt wiring powers the lights.

Electrical discharge lighting is designed to run on 277-volt wiring. A three-phase, four-wire distribution system running at 277 volts is used for high voltage lighting like LED arrays and fluorescent lights. Electricians can run 277 volts off 480-Volt AC circuits.

A 277/480V, three-phase system can provide single phase or three-phase power at 277 volts or 480 volts. Electrical distribution systems with 277-Volt wiring use step down transformers to provide either 240-Volt or 120-volt power as required. Residential AC circuits use power at 120 amps and 277 volts. Wiring of a 277/480-Volt system can supply both industrial and residential users. Using 277-Volt wiring permits more lights to be powered by a single branch circuit. This reduces the amount of high voltage wiring that must be installed to connect banks of LED or fluorescent lights, or appliances.

The National Fire Protection Association (NFPA) publication 70E, also called the National Electrical Code (NEC), defines electrical safety standards in the United States. Alternating current (AC) 277/480-Volt systems must have a 277-volt rating based on the National Electric Code (NEC). Article 210 of the National Electrical Code addresses 277- and 480-volt branch circuits. Section 215.10 of the NEC mandates ground-fault protection of equipment (GFPE) on branch of a 277/480-Volt circuit. Switches are used to control the flow of power to lighting. The NEC prohibits voltage between circuits from exceeding 300 volts. On 277/480V systems, the voltage is checked between any powered leg of the Y and the circuit’s ground. Yellow, brown and orange wires typically identify the ungrounded wires in a three-phase, four-wire, 277-volt system.

Wiring carrying 277 volts can create an arc flash hazard. The NEC states that alternating current wiring carrying more than 50 volts must be grounded unless one of several exemptions is met. According to “Handbook of OSHA Construction Safety and Health” by Charles Reese et al., grounding is not required “… if the system is nominally rated 480Y/277 volt, 3-phase, 4-wire in which the neutral is used as a circuit conductor.” The grounded conductor wire is identified by its gray color.